【NSF】Email alarm shows network anomaly detection alert (netstack)
Issue Description
The NSF device did not experience a significant increase in traffic or sessions during the alarm period. However, the user received an email notification indicating a network anomaly detection alert.
Error/Warning Logs

Handling Process
- Verify the throughput and session data to identify any significant traffic increments during the specified time.
- Verify if there is an increase in sessions during the specified time.
Root cause
False alarm
Solution
Install patch KB_AF_alarm_netstack_2024121000088_8095SP1.bin
KB_AF_alarm_netstack_2024121000088_8095SP1
note: The patch does not restart service of device.