[Hardware troubleshooting] Server memory initialization error handling for SN starting with FBH
Problem Description
Logs BMC sel log Alerting memory initialization Error, with Error code 0x302D/302E. After cross-memory, the Alerting follows the memory. Attached BIOS, BMC firmware
FBH BIOS,BMC.zip ( 72.72M )

solution
Step One: Enter BMC and View Time log. There is a memory initialization error with Error code 0x302D/302E. Check that the BMC Version is 3.06.10.03 or Version.
Step Two: Upgrade BMC and BIOS firmware to version 3.06.10.09 or above.
Cause:
- For devices Version BMC versions lower than 3.06.10.09, if memory generates Oddbit CE during the BIOS training phase, an initialization error will be reported to the BMC with Error code 0x302D/302E.
- The BMC Version the device is 3.06.10.03, which is lower than 3.06.10.09. There is a problem that the BIOS self-check memory standard is strict and the BMC alarm Alerting Error memory initialization error.
- In fact, memory CE Yes correctable Error. The laboratory conducted longTime stress testing on the memory that Alerting the alarm and found that the equipment was running stably and aligned with the manufacturer. It was comprehensively determined that the memory that generated the 0x302D/302E Alerting Yes Connected memory that met the standards.