[IAG] Audit rule base update failed

Problem Description

Audit rule base update failed

Effective troubleshooting steps

  1. Check that the application identification library and URL library are updated normally
  2. Backstage execution of sh -x /ac/module/actrace/scripts/ntrace_updater still fails
  3. The device is connected to the Internet normally
  4. Confirm that the rule base server connection is normal
    wget -T20 -t3 'update1.sangfor.net/ac/ntrace/1.0/update.php?u=0000' -O /tmp/ntrace_uplist
  5. cd /ac/module/actrace/new_trace/update_cache ;
    ll -trl;
    Check whether the audit rule base file already exists

solution

Execute ll -trl;rm IMRule_Pc.zip; to delete the buffer.
Re-pull the audit rule base
sh -x /ac/module/actrace/scripts/ntrace_updater 106 0;